Dual-axis control via one IP address, support CiA402
EtherNet/IP communication
Support operation modes: Profile Position, Profile Velocity, Homing
2*4 digital inputs, 2*2 optically isolated digital outputs include alarm and brake
Low noise and vibration, smooth motion
20-50VDC supply voltage, max 2.2A output current
Over voltage, over current, motor cable error protection, etc.
STO optional
2EM3EIP series drives support operating modes: Profile Position (PP), Profile Velocity (PV), and Homing (HM). The products can be matched with most of master station such as Beckhoff, Omron, Keyence, Panasonic etc.